Installation_14xRTAF_Mater_Dei_Hospital01_Malta.jpg

Challenge

Mater Dei Hospital in Malta has 250,000m² of space with some 825 beds and 25 operating rooms. When it opened in 2007, 14 chillers were installed however the system is now obsolete and in bad condition due to the climate and proximity to the sea.

The hospital had multiple compressors failing and coils not functioning. They were looking to replace their costly and dysfunctional existing system with one new more efficient, reliable, and flexible HVAC installation. The provider should be more flexible, polyvalent and reactive than the previous one.

There were several constraints to this project:
• The space availability
• The capability of running at full load up to 50°C and above
• The availability of a smart system to sequence the units and manage the whole plant including pumps and water-cooled units.

Solution

During the customers’ selection process, our local Trane team looked for opportunities to maximize energy efficiency savings with good Return on Investment. As with many hospitals, cooling and heating occurs simultaneously: the perfect opportunity to re-use cooling energy by generating heating with water-to-water heat pumps.

Trane implemented an energy efficient and extra low noise full HVAC solution comprising 14 RTAF Sintesis air-cooled chillers with adiabatic cooling systems and three RTWF water-to-water heat pumps. The installation was completed with a Tracer SC management system and a five-year maintenance contract with Trane. The units have been installed both on the hospital roof and in the technical room.

Our reliable, world-class equipment and our efficient service teams were key considerations.

Results

The largest medical facility of the island significantly reduced their consumption of fossil fuel and related CO2 footprint.

Substantial energy savings have been achieved. In one year, the system reduced fuel consumption – and the tons of CO² emitted – by 23%. "The hospital has already saved 1.4M litres of heating fuel and 3759 tones of CO2 emissions" said Ramon Tabone, Senior Mechanical Engineer at the hospital. The facility lower operating costs can also be attributed to the heat recovery installation that is used both for sanitary water and comfort heating.

This successful installation is a good example of the excellent collaboration between Mater Dei Hospital facility managers and our teams.



Related stories

Project highlights

Location: Malta

Market application: Healthcare

Customer need: Comfort cooling

Products installed: • 14 x Sintesis Prime RTAF air-cooled Chiller • 14 x Adiabatic cooling systems • Energy saving option: Heat recovery • 3 RTWF water-to-water HeatPumps • Tracer SC management system • 5-year Maintenance contract

Cooling Capacity: 3000 kW

Social media: Read more

Featured products

Product name: Sintesis Prime RTAF Air-Cooled Chiller

At a glance:

  • Low energy consumption: high full load (EER), seasonal comfort cooling (SEER) and process cooling (SEPR-HT and SEPR-MT) efficiencies
  • Ultra wide operating map both on airside and waterside
  • Highly configurable product design and options to meet specific performance requirements and budget needs
  • Trane design and manufactured semi-hermetic screw compressor technology. Fixed and variable speed versions, plus variable Volume Index models to reach remarkable efficiency levels.
  • Trane-patented flooded evaporator CHIL (Compact - High Performance - Integrated design - Low charge) design

Product page

Featured products

XStream™ RTWF XSE Water-to-Water Heat Pump

Product name: XStream™ RTWF XSE Water-to-Water Heat Pump

At a glance:

  • Variable Vi compressor with permanent magnet motor, AFD as standard
  • Market-leading full and part load efficiencies
  • Minimized refrigerant charge with CHILL falling film evaporator

Product page